Model
Product Photo
Description
Product Use
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIVERAD - Series
FULL KIT - SUBMARINE ROBOT KIT Underwater Explorer Submarine.
- DiveRAD-ST & DiveRAD-P Full Kit.
- DiveRAD-ST Search tool detects Gamma with Optional Neutron Detector.
- DiveRAD-P Plume detector for Alpha, Beta, Gamma Radiation particulates. Detects Chemical and Biological Contamination.
Includes submersible, video, and base station electronics. Tethered data stream and onboard data storage serial port. 100 feet depth.
Portable.
- Undersea Forensics:
Water, Ships, Ports, Questionable underwater objects
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MEDA-SP
Two detectors Internal-t-1190 Alpha, Beta, Gamma detector. External-submersible Gamma detector. Local readout. Use anywhere. Great for First Responders.
Portable.
- Drinking-Water and Wastewater.
- Ground and Surface Waters
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chemical, Biological, & Radiation Water Safety Monitor
Real-Time Continuous detection of 4-6 Radionuclides, 6 major chemical contaminants, and Total Fecal and E-Coli Bacteria. USB port for data downloads to PC or Tablet.
Suitcase model in wheeled case (MiniTect-H2O-SC). Backpack model = (2) backpacks (MiniTect-H2O-BP).
Portable.
- Drinking Water and Wastewater.
- Ground and Surface Waters
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEX-ABG-9TT
Test & Treat for radioactive biological & contamination. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring & treatment of drinking water 24/7. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.
Portable or Installed.
- Facilities for vulnerable populations
- Hospitals, Schools, Government Buildings on Water Inlet / Outlet Pipes
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEX-BETA
Beta detector water monitor /controller. Detects at BETA PAG level. Local readout. Computer interface.
Portable or Installed.
- Facilities for vulnerable populations
- Hospitals, Schools, Government Buildings on Water Inlet / Outlet Pipes
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Facility Drinking Water Radiation Safety Monitor.
Continuous Real-Time. Detects GAMMA, ALPHA, BETA. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Data archive/retrieval. Computer interface
Measures at or below EPA/DHS PAG Levels. Protective Action Guideline and Military Drinking water limits. Alpha, Beta, Gamma.
Portable or Installed.
- Facilities for vulnerable populations
- Hospitals, Schools, Government Buildings on Water Inlet / Outlet Pipes
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Mounted or Wheeled Base. Detects GAMMA. Monitor ground, surface water, industrial liquid-waste-stream. Useful in complying with discharge requirements for wastewater.Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.
Installed.
- Drinking-Water Treatment Utilities
- Wastewater Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEXGEN-SSS
Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
Installed.
- Drinking-Water Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PEMO-7
Detects Gamma. Flow rate is not a factor. Constant check and quick alarm of waterborne radioactive contamination flowing thru one or more pipes. Single channel (SCA) and multichannel analyzer (MCA) models. Data archive/retrieval. Computer interface.
Installed.
- Drinking-Water Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PEMO-7
Detects Gamma. Flow rate is not a factor. Constant check and quick alarm of waterborne radioactive contamination flowing thru one or more pipes. Single-channel (SCA) and multichannel analyzer (MCA) models. Data archive/retrieval. Computer interface.
Installed.
- Drinking-Water Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PEMO-7LE
Flow rate is not a factor. Detects Gamma. Constant check and quick alarm ofwaterborne radioactive contamination flowing thru one or more pipes. Single-channel (SCA) and multichannel analyzer (MCA) models. Local readout. Computer interface.
Portable.
- Drinking-Water Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RADIUM-TA Series
RADIUM-MCA identifies specific Radium nuclides. The system gives on-site measurements, detects Radium, Sensitivity 3 Pico curie per Liter Total Radium.
Portable or Installed.
- Small Water Systems
- Drinking-Water Treatment Utilities
- Homeland Security
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RADON-7
Analog. Continuous. Radon Alpha Scintillation system and combines a modified PAS-8 Alpha Scintillation Probe plus FLO-9 water-flow-thru sampler. Monitor aquifer for rising Radon levels in complying with EPA and Water Districts standards. Optional computer interface.
Field use:
- Water Reservoirs Aquifer
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAWA-GP Series
Detects Gamma. Single detector (RAWA-GP). Dual detector (RAWA-BGP) for Beta & Gamma. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Useful in complying with discharge requirements for wastewater. The modular system allows function changes or additions and rapid repair in the field.
- Wastewater Utilities
- Fracking
- Mining
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SSS-22P Series
. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–IncludingØTritium, Carbon-14, & Sulphur-35 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample (SSS-12P), 3 samples (SSS-22P), 3 samples with a Multichannel Analyzer (SSS-22-MCA), suitcase version of SSS-22P (SSS-22PAL), lab version of SSS-22P (SSS-22LAB). Local readout and alarm. Computer interface.
Field Use:
- Anywhere water needs a quick check.
- Nuclear Medicine
- Laboratories
- Drinking-Water and Wastewater;
- Ground and Surface Waters
- Homeland Security
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .